Abstract

BackgroundAfter traumatic brain injury (TBI), the ability of cerebral vessels to appropriately react to changes in arterial blood pressure (pressure reactivity) is impaired, leaving patients vulnerable to cerebral hypo- or hyperperfusion. Although, the traditional pressure reactivity index (PRx) has demonstrated that impaired pressure reactivity is associated with poor patient outcome, PRx is sometimes erratic and may not be reliable in various clinical circumstances. Here, we introduce a more robust transform-based wavelet pressure reactivity index (wPRx) and compare its performance with the widely used traditional PRx across 3 areas: its stability and reliability in time, its ability to give an optimal cerebral perfusion pressure (CPPopt) recommendation, and its relationship with patient outcome.Methods and findingsFive hundred and fifteen patients with TBI admitted in Addenbrooke’s Hospital, United Kingdom (March 23rd, 2003 through December 9th, 2014), with continuous monitoring of arterial blood pressure (ABP) and intracranial pressure (ICP), were retrospectively analyzed to calculate the traditional PRx and a novel wavelet transform-based wPRx. wPRx was calculated by taking the cosine of the wavelet transform phase-shift between ABP and ICP. A time trend of CPPopt was calculated using an automated curve-fitting method that determined the cerebral perfusion pressure (CPP) at which the pressure reactivity (PRx or wPRx) was most efficient (CPPopt_PRx and CPPopt_wPRx, respectively).There was a significantly positive relationship between PRx and wPRx (r = 0.73), and wavelet wPRx was more reliable in time (ratio of between-hour variance to total variance, wPRx 0.957 ± 0.0032 versus PRx and 0.949 ± 0.047 for PRx, p = 0.002). The 2-hour interval standard deviation of wPRx (0.19 ± 0.07) was smaller than that of PRx (0.30 ± 0.13, p < 0.001). wPRx performed better in distinguishing between mortality and survival (the area under the receiver operating characteristic [ROC] curve [AUROC] for wPRx was 0.73 versus 0.66 for PRx, p = 0.003). The mean difference between the patients’ CPP and their CPPopt was related to outcome for both calculation methods. There was a good relationship between the 2 CPPopts (r = 0.814, p < 0.001). CPPopt_wPRx was more stable than CPPopt_PRx (within patient standard deviation 7.05 ± 3.78 versus 8.45 ± 2.90; p < 0.001).Key limitations include that this study is a retrospective analysis and only compared wPRx with PRx in the cohort of patients with TBI. Prior prospective validation is required to better assess clinical utility of this approach.ConclusionswPRx offers several advantages to the traditional PRx: it is more stable in time, it yields a more consistent CPPopt recommendation, and, importantly, it has a stronger relationship with patient outcome. The clinical utility of wPRx should be explored in prospective studies of critically injured neurological patients.

Highlights

  • Traumatic brain injury (TBI) is an important global public health problem as a major cause of traumatic death and disability, especially in young people [1,2]

  • Conclusions wavelet pressure reactivity index (wPRx) offers several advantages to the traditional pressure reactivity index (PRx): it is more stable in time, it yields a more consistent optimal CPP (CPPopt) recommendation, and, importantly, it has a stronger relationship with patient outcome

  • The clinical utility of wPRx should be explored in prospective studies of critically injured neurological patients

Read more

Summary

Background

After traumatic brain injury (TBI), the ability of cerebral vessels to appropriately react to changes in arterial blood pressure (pressure reactivity) is impaired, leaving patients vulnerable to cerebral hypo- or hyperperfusion. The traditional pressure reactivity index (PRx) has demonstrated that impaired pressure reactivity is associated with poor patient outcome, PRx is sometimes erratic and may not be reliable in various clinical circumstances. We introduce a more robust transform-based wavelet pressure reactivity index (wPRx) and compare its performance with the widely used traditional PRx across 3 areas: its stability and reliability in time, its ability to give an optimal cerebral perfusion pressure (CPPopt) recommendation, and its relationship with patient outcome

Methods and findings
Conclusions
Author summary
Introduction
Methods
Results
Limitations
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.