Abstract

A spontaneous cerebrospinal fluid leak can sometimes only become apparent following grommet insertion and usually represents dehiscence of the tegmen tympani, which is an uncommon condition. This report aimed to reaffirm the importance of recognising this unusual presentation and outline management options. A 63-year-old man with conductive hearing loss and type B (flat) tympanometry underwent grommet insertion into his left ear, which resulted in cerebrospinal fluid otorrhoea. A defect of the tegmen tympani was found. This was successfully repaired via a transmastoid approach using a multi-layered grafting technique. Dehiscence of the tegmen tympani is uncommon and may only come to light following grommet insertion, which may be problematic for the uninformed otolaryngologist. Education is important to ensure early recognition and appropriate management.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.