Abstract

Profound hypothermia with circulatory arrest is an important surgical adjuvant that allows protected cessation of cerebral blood flow for a brief period. In seven patients undergoing this procedure, continuous spectroscopic measurement of cerebral hemoglobin oxygen saturation was performed. Circulatory arrest at 18 degrees C was associated with a significant progressive desaturation (p < 0.01) of residual cerebral hemoglobin. Arrest time varied based on operative complexity (range 10 to 65 minutes), and a negative linear correlation between arrest time (y) and oxygen saturation (x) was noted (y = -0.87 x + 64). Five patients whose saturation remained above 35% had no neurological injury attributable to hypoxia. One patient (Hunt and Hess Grade 0) whose saturation fell below 35% had evidence of a global hypoxic injury at postmortem examination. Spectroscopically measured cerebral hemoglobin saturation (cerebral oximetry) may be used to monitor metabolic activity during circulatory arrest. Although the clinical utility of such monitoring cannot be established at this time, the potential may exist to prolong the safe duration of induced circulatory arrest for cerebral protection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.