Abstract

Air embolism in the arterial system is a very rare but potentially fatal complication of percutaneous transthoracic needle biopsy or marking. We report a case of a patient with interstitial pneumonia associated with Sjögren syndrome, who presented with systemic arterial air embolism as a complication of computed tomography-guided marking of the lung. The air inflow route was depicted clearly on computed tomography from the peripheral pulmonary vein that crossed the needle pathway to the left atrium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.