Abstract

Cephalic vein (CV) cut-down for totally implantable central venous access devices (TICVADs) is not frequently used due to its low success rate. We compared the outcomes of CV cut-down using preoperative ultrasonography (US) performed by experienced surgeons versus surgical residents. From December 2015 to December 2017, 10 surgeons implanted 212 TICVADs using CV cut-down with preoperative US. The surgeons were divided into two groups of five each: surgical residents (Group A, n=124 procedures) and experienced surgeons (Group B, n=88 procedures). Duration of operation time, completion rate, and complications were retrospectively analyzed. The completion rate was significantly higher in Group A (98.4% versus 92.0%, p=0.04). Duration of operation time (45.2±14.5 versus 42.0±13.1 minutes, p=0.22), rates of early complications (1.6% versus 1.1%, p=0.77) and late complications (3.2% versus 2.3%, p=0.68) were equivalent between the two groups. No fatal complications occurred in either group. CV cut-down can be safely performed by surgical residents under the use of preoperative US.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.