Abstract

Annular shaped pile groups are a very common foundation layout for onshore wind turbines and other slender structures. In this study, their performance under vertical loads of moderate to high eccentricity, including moment rotation response and bearing capacity, was investigated by centrifuge testing on small scale physical models embedded in kaolin clay. To identify experimentally the capacity of the examined pile groups under different load paths, the model foundations were loaded monotonically until a clear collapse mechanism was achieved. The testing procedure and the proposed interpretation methodology can be easily adapted to load paths or pile layouts other than those considered in the current study. The experimental data can be adopted as a useful benchmark for mathematical models aimed at predicting the response of pile groups to complex load paths. The results of this testing program can also be used to assess the degree of conservatism of current methods adopted by industry for the design of piled foundations subjected to eccentric loads.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.