Abstract

A total of 25 centrifuge model tests were conducted to investigate the pullout capacity of a suction pile with various mooring line inclination angles and padeye positions. They represent twenty five sets of model tests with each set being repeated at least once. Median values of the duplicate measurements were selected for detailed analysis. This paper describes the details of the centrifuge model test preparation, procedures, instrumentation, test results, and discussions.