Abstract

Hickman-type tunnelled catheters (Hickman), peripherally inserted central catheters (PICCs), and totally implanted ports (PORTs) are used to deliver systemic anticancer treatment (SACT) via a central vein. We aimed to compare complication rates and costs of the three devices to establish acceptability, clinical effectiveness, and cost-effectiveness of the devices for patients receiving SACT. We did an open-label, multicentre, randomised controlled trial (Cancer and Venous Access [CAVA]) of three central venous access devices: PICCs versus Hickman (non-inferiority; 10% margin); PORTs versus Hickman (superiority; 15% margin); and PORTs versus PICCs (superiority; 15% margin). Adults (aged ≥18 years) receiving SACT (≥12 weeks) for solid or haematological malignancy from 18 oncology units in the UK were included. Four randomisation options were available: Hickman versus PICCs versus PORTs (2:2:1), PICCs versus Hickman (1:1), PORTs versus Hickman (1:1), and PORTs versus PICCs (1:1). Randomisation was done using a minimisation algorithm stratifying by centre, body-mass index, type of cancer, device history, and treatment mode. The primary outcome was complication rate (composite of infection, venous thrombosis, pulmonary embolus, inability to aspirate blood, mechanical failure, and other) assessed until device removal, withdrawal from study, or 1-year follow-up. This study is registered with ISRCTN, ISRCTN44504648. Between Nov 8, 2013, and Feb 28, 2018, of 2714 individuals screened for eligibility, 1061 were enrolled and randomly assigned, contributing to the relevant comparison or comparisons (PICC vs Hickman n=424, 212 [50%] on PICC and 212 [50%] on Hickman; PORT vs Hickman n=556, 253 [46%] on PORT and 303 [54%] on Hickman; and PORT vs PICC n=346, 147 [42%] on PORT and 199 [58%] on PICC). Similar complication rates were observed for PICCs (110 [52%] of 212) and Hickman (103 [49%] of 212). Although the observed difference was less than 10%, non-inferiority of PICCs was not confirmed (odds ratio [OR] 1·15 [95% CI 0·78-1·71]) potentially due to inadequate power. PORTs were superior to Hickman with a complication rate of 29% (73 of 253) versus 43% (131 of 303; OR 0·54 [95% CI 0·37-0·77]). PORTs were superior to PICCs with a complication rate of 32% (47 of 147) versus 47% (93 of 199; OR 0·52 [0·33-0·83]). For most patients receiving SACT, PORTs are more effective and safer than both Hickman and PICCs. Our findings suggest that most patients receiving SACT for solid tumours should receive a PORT within the UK National Health Service. UK National Institute for Health Research Health Technology Assessment Programme.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.