Abstract

Aortic pressure can be estimated using one-dimensional arterial flow simulations. This study demonstrates that two peripheral pressure measurements can be used to acquire the central pressure curve through the patient-specific optimization of a set of system parameters. Radial and carotid pressure measurements and parameter optimization were performed in the case of 62 patients. The two calculated aortic curves were in good agreement, Systolic and Mean Blood Pressures differed on average by 0.5 and −0.5 mmHg, respectively. Good agreement was achieved with the transfer function method as well. The effect of carotid clamping is demonstrated using one resulting patient-specific arterial network.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.