Abstract

BackgroundWe report the clinical evaluation, quality of life and pain assessment in patients who had a femoral neck SPIRON endoprosthesis.MethodsThe study group consisted of 27 men in whom 35 femoral neck endoprosthesis were implanted (8 on the left side, 12 on the right side and 7 bilateral) due to idiopathic osteoarthritis of the hip (20 patients) or avascular femoral osteonecrosis (7 patients) in a mean 7-year follow-up.ResultsThe median pre-operative Harris Hip score (HHS) was 35.5 and post-operative 98.5 (p < 0.001). The median WOMAC HIP score was pre-operatively 57 and post-operatively 0 (p < 0.001). The median SF-12 score was pre-operatively 4 and post-operatively 33 (p < 0.001). The median pain assessment in VAS scale was 7 pre-operatively and 0 post-operatively (p < 0.001).ConclusionsThe results of all examined patients have changed significantly in every category showing that SPIRON endoprosthesis improved their quality of life and statistically reduced pain ailments. Moreover we have proved that higher BMI (> 30) is associated with worse operation outcomes.