Abstract

Numerous different designs of hemiarthroplasty are available but few have been compared within the context of a randomised controlled trial. Two-hundred patients presenting with a displaced intracapsular fracture of the hip were randomised to receive either a cemented Thompson hemiarthroplasty or a cemented smooth tapered stem hemiarthroplasty (Exeter Trauma Stem). All operations were undertaken or directly supervised by one surgeon using the same operative approach. Patients were followed up for 1 year from injury by a research nurse blinded to the treatment used. The smooth tapered stem was felt to present less operative difficulties compared to the Thompson prosthesis. There were no other statistically significant differences in outcomes between the two prostheses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.