Abstract

Purpose: The assessment of radiotoxicity for heterogeneously distributed tritium should be based on the subcellular dose and relative biological effectiveness (RBE) for cell nucleus. In the present work, geometry-dependent absorbed dose and RBE were calculated using Monte Carlo codes for tritium in the cell, cell surface, cytoplasm, or cell nucleus.Materials and methods: Penelope (PENetration and Energy LOss of Positrins and Electrons) code was used to calculate the geometry-dependent absorbed dose, lineal energy, and electron fluence spectrum. RBE for the intestinal crypt regeneration was calculated using a lineal energy-dependent biological weighting function. RBE for the induction of DNA double strand breaks was estimated using a nucleotide-level map for clustered DNA lesions of the Monte Carlo damage simulation (MCDS) code.Results: For a typical cell of 10 μm radius and 5 μm nuclear radius, tritium in the cell nucleus resulted in much higher RBE-weighted absorbed dose than tritium distributed uniformly. Conversely, tritium distributed on the cell surface led to trivial RBE-weighted absorbed dose due to irradiation geometry and great attenuation of beta particles in the cytoplasm. For tritium uniformly distributed in the cell, the RBE-weighted absorbed dose was larger compared to tritium uniformly distributed in the tissue.Conclusions: Cellular- and micro-dosimetry models were developed for the assessment of heterogeneously distributed tritium.