Abstract

Cell configurations with asymmetric and symmetric electrode geometries and different reference electrode positions were investigated on 50 mm×50 mm planar solid oxide fuel cells (SOFC). The reliability and accuracy of the polarization performance of individual electrodes were studied with respect to the electrode geometry and the reference electrode position. The results indicate that a centrally located reference electrode creates inactive electrolyte regions in the center of the cell, pushing the equipotential lines close to the electrode–electrolyte interface region and thus introducing error in the measurement of polarization performance. The potential of reference electrodes located at the corner of the electrode coating was not stable due to the steam build-up in the reference electrode region. Cells with a symmetric electrode geometry arrangement and reference electrodes located at the side of the working electrodes, away from the receiving end of the fuel and oxidant gases, were found to be suitable for performance evaluation in planar SOFC.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.