Abstract

The front velocity of transient ceiling becomes an important consideration for tunnel fire safety, which provide a prediction of travel time of ceiling jet. The previous model predictions of ceiling jet front velocity were developed in a natural ventilation tunnel. The effect of central mechanical exhaust system on the ceiling jet front velocity have not been revealed in the past. This work experimentally revealed smoke front velocity of ceiling jet in a tunnel under the effect of central mechanical exhaust system, and the relative location between fire source and central exhaust system were considered. It is found that, the relative direction of fire source and ceiling mechanical extraction opening has a great influence on the smoke front velocity of ceiling jet. Some previous models (Jones, Benjamin, and CFAST) all overestimate the smoke flow velocity of ceiling front; the predicted ceiling jet front velocity deduced by Jones and Benjamin have the maximum excessive deviation of about 60% and 98%, respectively, but the CFAST model is closer to the measurements with relatively higher front velocity. The Hinkley’s model can be well used to predict it with different central mechanical exhaust system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.