Abstract

BackgroundCatheter-related bloodstream infection (CR-BSI) is one of various complications related to hemodialysis (HD). As a result of the high rate of infection, the use of lock solutions for the prevention of CR-BSI has been studied. However, adverse effects of lock solution, such as increased emergence of strains resistant to antibiotics, which is an important concern, need to be investigated further. The aim of this study was to compare the efficacy of lock solution using a combination of cefazolin and gentamicin versus taurolidine and citrate in reducing CR-BSI in patients undergoing HD and to identify any adverse effects. MethodsA prospective observational study was performed at two dialysis centers. Patients using new tunneled central venous catheters (CVC) for HD were included. Patients with a tunneled CVC were assigned to receive either antibiotic lock solution (group 1: gentamicin 7mg/ml+cefazolin 12mg/ml+heparin 3500IU/ml) or lock solution with TauroLock-Hep500 (group 2: taurolidine citrate 4%+heparin 500 IU/ml) during the inter-dialysis period. The patients were allocated to these groups according to the hemodialysis center they were attending. ResultsA total of 145 CVCs were implanted in 127 patients and were followed for 15 months: 77 CVCs (65 patients) were placed in group 1 and 68 CVCs (62 patients) in group 2. There was no difference between the two groups with regard to CR-BSI (events per 1000 catheter-days: group 1=0.79, group 2=1.10; p=0.18) or exit site infection rates (events per 1000 catheter-days: group 1=2.45, group 2=1.83; p=0.37). The groups differed in ESI pathogens, with gram-positive oxacillin-resistant pathogens more frequent in group 1 (31.8% vs. 5.0%; p=0.003). The two groups were similar in mechanical complications. In the Cox regression analysis, the internal jugular vein site was a protective factor for all catheter removal complications (hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.19–0.91) and mechanical complications (HR 0.16, 95% CI 0.065–0.41); only ESI was a risk factor for all catheter removal complications (HR 1.79, 95% CI 1.04–3.07) and mechanical complications (HR 5.64, 95% CI 1.65–19.3). ConclusionsThe efficacy of both lock solutions was similar in preventing infections related to tunneled CVCs for HD. However, there were more oxacillin-resistant strains in patients who received antibiotic lock solution. Further studies are required to determine the optimal drug regimen and concentrations for lock solution and the associated adverse effects.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.