Abstract

Malfunctions in the water control circuitry on the RF cavities have induced beam movements in both the horizontal and vertical planes which have been observed by users. A possible cause of such movements could be a cavity higher order mode (HOM). The SRS cavity HOM spectra exhibits some dipole modes which could produce such an effect and investigations have been performed on the SRS which have tried to identify a HOM as the cause of the beam position movement. The data presented here is the result of these investigations, whereby, cavity tuner position, cavity temperature and cavity HOM spectra have been monitored (with beam) as a function of electron beam and photon beam positions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.