Abstract

Cavitation sometimes occurs serious problems in hydraulic system. The problems become especially obvious in water hydraulic system because of higher saturated vapor pressure of water comparing of that of oil. This study is focused on cavitation phenomenon in a spool valve for Aqua Drive System. A spool valve model was made of transparent acrylic resin for visualization of cavitation phenomenon. Vibration and noise from the model were measured with changing the cavitation number. As a result, the vibration and noise are enhanced for the smaller cavitation number and the larger opening gap of a control port. It is, however, noticed that vibration and noise become large for some specific condition regardless of large cavitation number. It is revealed that these phenomena depend on cavitation type from visualization results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.