Abstract

Three centrifugal pump impellers fabricated of Inconel were subjected to endurance testing under cavitating conditions with sodium and with molten salt (fused fluorides) at temperatures of 1050–1400 F. The tests were run (one with sodium and two with molten salt) at or near pump design head and flow conditions to establish the extent of impeller damage sustained during long periods of operation and to observe the effects upon performance. Descriptions are provided of the test impellers and volutes, of the experimental apparatus, and of the test operations. The cavitation damage is described by the effects on hydraulic performance and with photomicrographs and metallurgical analyses. Damage was manifested by the formation of pits in excess of 1/4 in. in depth. No change in performance was detected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.