Abstract

During the hydrostatic test of an ultra supercritical unit, the water wall burst occurred. The causes of leakage were analyzed by means of macro observation, chemical composition analysis, metallographic examination and hardness test. The results show that the formation of cracks is related to fatigue, extending from the inner wall to the outer wall, accompanied by corrosion and oxidation. Fatigue is the main cause of transverse crack formation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.