Abstract

A large area of leakage occurred in plate heat exchanger of a power plant. The causes of leakage were analyzed by means of appearance analysis, chemical composition analysis, microstructure detection and energy spectrum analysis. The results show that Cl ion exists in the environment of the leaking heat exchanger, which has strong corrosiveness to austenitic stainless steel. At the same time, there are machining residual stress and internal stress produced by internal medium in the heat exchanger, which lead to stress corrosion and cracking.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.