Ion chromatography with self-regenerating suppression and conductivity detection was used for the simultaneous determination of Na +, NH 4 +, K +, Mg 2+ and Ca 2+ in melted snow samples from high-alpine sites. Concentrations in the samples showed a high variability and were in the range of 0.3 to 800 μg.kg. Samples with concentrations higher than 2 μg/kg representing summer snow were analyzed using a 100-μl sample loop. In order to determine the low concentrations in winter snow samples (< 2 μg/ kg), preconcentration of 2-ml samples was applied resulting in improved detection limits of 0.1–0.4 μg/kg depending on the cation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.