Abstract

Abstract A report is given of the practical considerations involved in the cathodic protection of the coated steel gas main distribution system in New Orleans. Topics discussed include topography and soils in New Orleans, types of gas mains used in system, use of coatings, use of galvanic anodes, experience with rectifiers and ground beds, use of insulated joints, importance of educational programs, and cost of cathodic protection. Data are given for a portion of one periodic rectifier survey and yearly tests on three galvanic anodes. Results secured were good. It was found that successful operation of cathodic protection in New Orleans could be materially aided by observing the following procedure: (1) Secure reasonably good coating of the mains to be protected, (2) Maintain the systems to be protected electrically continuous, and free from electrical contact with other metallic subsurface structures, (3) Maintain the electrical potential of the systems to be protected at least —0.85 volt to a copper sul...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.