Abstract
This study is to acquire the confirmation data regarding the cathodic protection characteristics for reinforced concrete beam specimens with zinc sacrificial anode in 15% salt water. It was possible to confirm the performance of sacrificial anode cathodic protection system by the measurement of potentials and concrete resistivity for the reinforced concrete beam specimens applied with zinc sacrificial anode in mortar topside of the concrete specimens. The corrosion potential and cathodic protection potential were measured by potentiostat, and 4 hour depolarization potentials were measured after disconnecting with anode for 4 hours. It was confirmed that the cathodic protection for reinforced concrete structures by means of zinc sacrificial anode were very effective corrosion protection technology in marine environments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.