Abstract

The stripping voltammetric behaviour of drotaverine hydrochloride (DvCl) was studied using a hanging mercury drop electrode (HMDE). The adsorptive stripping response has been evaluated with respect to pH, accumulation time, accumulation potential, scan rate and other variables. Differential pulse DP mode; over the potential range − 400 to − 1200 mV, is used in the presence of 0.04 M Britton–Robinson buffer pH 2. Cyclic voltammetric study indicates that the reduction process is irreversible and controlled by adsorption. The response of DP technique is linear over the concentration range 21.70–257.34 ng/ml. Limit of detection and limit of quantification were 3.15 and 10.50 ng/ml, respectively. The proposed method was successfully applied for the determination of the drug in commercial tablets and spiked human urine samples.