Abstract

Based on an analysis of the Joule heating of emitters by thermionic current, new methods and criteria are proposed for evaluating vacuum breakdown cathode-initiated in a pulse regime for an arbitrary cathode shape. The applicability of the proposed methods and validity of the new criteria are confirmed by the results of experiments using nanosecond pulses applied to coaxial copper electrodes with a gap width of d=0.2 mm and an area of S=2500 mm2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.