Abstract
The electron emission from the cathode of a high-voltage low-pressure glow discharge, under various conditions, was studied with the aid of a simple electron emission microscope. The experiments were made in a roughing-pump atmosphere at a pressure of the order of 0·1 torr. Particular attention was paid to the influence of cathode temperature in the range 20-300°C. Organic contaminants appeared to spread over the cathode by an ion bombardment assisted process of surface migration at low temperatures, but decomposed to leave an immobile residue above about 150°C. The surface could be `cleaned' by ion bombardment at an elevated temperature (250°C), and then appeared to remain in a relatively clean state while hot. Direct contamination from the gaseous atmosphere was not detected. This interpretation is discussed in regard to the glow-to-arc transition, to vapour-deposition processes and to vacuum breakdown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.