Abstract

The results of studies of cathode configuration influence on high current low- inductance vacuum spark (HLVS) plasma dynamics are presented in this work. The research was carried out on “PION” installation using shadowgraphy method. Molecular nitrogen laser (λ = 337 nm) was used as a radiation source. It was determined that the HLVS behavior changes with the increase of number of discharges. In a fresh electrode system (less than 200 discharges) the dependence of constriction position on the discharge trigger position is observed during HLVS development. Also, high gradients of plasma density and secondary constrictions are observed. In a previously exploited electrode system (more than 300 discharges) HLVS behavior changes: plasma density gradients become less expressed, secondary constrictions disappear. In electrode systems with highly developed cathode surface plasma density gradient distribution pattern only slightly changes from discharge to discharge, e.g. the discharge becomes more stable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.