Abstract

BackgroundThe combined spinal-epidural technique for labor analgesia has several advantages over the traditional epidural technique, including faster onset, greater maternal satisfaction, and decreased need for physician boluses. Proponents of the epidural technique criticize the combined spinal-epidural technique, arguing that the epidural catheter remains untested and thus may not be reliable if needed for surgical intervention. We compared failure rates and time of failure between techniques in our tertiary-care academic practice. MethodsData regarding failed catheters were collected from October 2012 to September 2014 as part of our Quality Assurance program. Failed catheters were defined as any catheter replaced after it was considered to be properly placed and then determined to be intravascular, one sided or resulting in poor maternal analgesia or anesthesia. ResultsA total of 5487 analgesics were performed (3980 combined spinal-epidural; 1507 epidural). Eighty-five combined spinal-epidural catheters (2.1%) and 59 epidural catheters (3.9%) were replaced during labor (P<0.001). Mean time to replacement was 512±422min and 354±300min for the combined spinal-epidural (n=80) and epidural (n=57) groups, respectively (P=0.02). Median time to replacement was 398 [IQR 131–578] min and 281 [IQR 186–767] min for combined spinal-epidural and epidural groups, respectively (P<0.0001). ConclusionWe were able to demonstrate that catheters placed using a combined spinal-epidural technique were less likely to fail during labor and that the time to detection of a failed catheter was significantly longer in the combined spinal-epidural group. Our findings validate the combined spinal-epidural technique as reliable for labor analgesia and tend to refute the theory of the untested catheter.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call