Abstract
Phase separation is analysed for a two-phase mixture flowing through dividing tee junctions with a small ratio of branch to main pipe diameter. The case of a stratified flow in a horizontal main pipe connected to a horizontal, vertical upward or vertical downward branch is considered. A model is developed on the basis of the available data banks. A wide range of parameters is covered (pressure, 0.2–7 MPa; main pipe diameter, D = 80–284 mm; branch diameter, 4–34 mm). The model has been introduced in the CATHARE Pressurized Water Reactor (PWR) safety code, thereby leading to a considerable improvement of the code predictions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.