Abstract

In traction networks, voltage drop in catenary line is a general problem being faced. By injection of capacitive reactive power to the current controlled active line-side converter losses can be reduced in locomotives. Then catenary voltage is compared with the reference value and the error is fed to PI controller. The controller generates a reference value of converter current which will lead to reactive power injection. The catenary parameters are identified by harmonic current injection. The performance of the proposed control strategy is evaluated in MATLAB- Simulink. The proposed method is applied to reduce the voltage drop in catenary line of locomotive and the optioned result are compared with those of the conventional method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.