Abstract

ABSTRACT The ability of ultrasound-catalyst hybrid system in degradation of HA, and survey the effective parameters in degradation is the objectives of the present study. The characteristics of the synthesised catalyst was investigated by SEM, XRD and UV-DRS. The performance of the system in pollutant removal was investigated using the OFAT (One Factor at a Time Method) method. The kinetics of the process, mechanism and the reusability of the catalyst were determined in optimised conditions. The results indicated that pH = 3, catalyst dosage = 400 mg/l, HA concentration = 5 mg/l have best efficiency (74%). Superoxide and hydroxyl radicals were considered as the main cause of HA degradation. Catalyst stability was investigated in 5 replicates and verified. The reduction in TOC obtained 45%. The overall results show that the ultrasound Fe–doped TiO2 hybrid system has partial promising performance in degradation of HA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.