Abstract

Casted titanium for dental crowns has been investigated by means of X-ray Photoelectron Spectroscopy (XPS), X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The samples were prepared according to the Ohara process. XRD analysis revealed that the investment consisted essentially of SiO 2, Mg 2P 2O 7, SiO 2 · H 2O and Mg 2SiO 4. SEM experiments combined with EDX analysis revealed the following atomic concentrations Si (62.6%), Mg (19.7%), P (17.1%), and Ca (0.6%). After casting, the titanium samples exhibit a rough and irregular surface, and XRD analysis indicated that titanium contains essentially the α phase and traces of the β phase. After demoulding titanium samples, the investment side which was in contact with titanium was black colored, proving the reaction between titanium and the investment. XPS analysis performed on this side of the investment indicated that the Si 2p peak presents a shoulder on the low binding energy side and thus suggest that SiO 2 has been transformed into metallic Si.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.