Abstract

The first part of this article (February issue) dealt with a failure in a boiler raising steam by using heat from a 7% SO2‐in‐air mixture; the protective corrugated cast iron shell round the boiler tubes opened, exposing them to oxidation. The present case concerns cracking of a 22‐in. connecting main between two SO3 absorbers; this was found to be caused by SO3 passing into the cast iron through the graphite flakes and attacking the adjoining ferrite.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.