The first part of this article (February issue) dealt with a failure in a boiler raising steam by using heat from a 7% SO2‐in‐air mixture; the protective corrugated cast iron shell round the boiler tubes opened, exposing them to oxidation. The present case concerns cracking of a 22‐in. connecting main between two SO3 absorbers; this was found to be caused by SO3 passing into the cast iron through the graphite flakes and attacking the adjoining ferrite.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.