Abstract

BackgroundAngulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations.MethodsThree Osseolink implants were placed in three reference models with different angles (parallel, 15° and 30°). Impressions of each model were made with three techniques (n = 10 per group): indirect, unsplinted direct, and acrylic resin-splinted direct technique. Impressions were poured with type IV dental stone. Inter-implant distances were measured for casts using a coordinate measuring machine, and the deviations from the reference models (Δr) were calculated. Data were analyzed using one-way ANOVA followed by post hoc tests to detect significance between groups (α = 0.05).ResultsThis study showed that the deviations in micrometers from the reference model were the least for acrylic resin-splinted direct technique (Δr1 = 49.96, Δr2 = 50.36) versus indirect (Δr1 = 93.8, Δr2 = 90.9) and unsplinted direct techniques ((Δr1 = 67.07, Δr2 = 68.66) in 30° angulated implant situation (p value < 0.0001* for both Δr1 and Δr2). In 15° angulated implants, both the acrylic resin-splinted direct (Δr1 = 44.64, Δr2 = 45.58) and unsplinted direct techniques (Δr1 = 47.39, Δr2 = 55.28) were more accurate than indirect technique (Δr1 = 64.8, Δr2 = 68.3) (p value < 0.0001* for both Δr1 and Δr2). While in parallel condition, no difference was found between all three techniques (p value = 0.085, 0.056 for Δr1 and Δr2, respectively).ConclusionsThe impression technique affected the accuracy of definitive casts. The acrylic resin splinted direct technique produced the most accurate casts, followed by direct unsplinted and indirect techniques. Furthermore, implant angulation affected the impression accuracy. When implant angulation increased from parallel implants to 30°, the forces of deformation increased, which resulted in increased distortion.

Highlights

  • Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast

  • Post hoc test showed that indirect technique was significantly (p < 0.05) less accurate than direct unsplinted and direct splinted techniques which were not significantly different from each other (p > 0.05) for Δr1 and Δr2

  • Post hoc test showed that indirect technique was significantly (p < 0.05) less accurate than direct unsplinted which was significantly (p < 0.05) less accurate than direct splinted techniques for Δr1 and Δr2

Read more

Summary

Introduction

Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. Precise working casts are essential to fabricate passively fitting implant prostheses. Accurate implant impressions play a significant role and serve as a starting point in the process of producing good working casts [1]. The comparative accuracy of the impression techniques becomes a significant issue in consideration of passive fit. Impression technique, type of impression material [3], splinting or non-splinting impression copings, type of splinting material, and number and angulation of implants [4] are the factors that affect the accuracy of impression.

Methods
Results
Discussion
Conclusion