Abstract

Simultaneous construction of adjacent projects may lead to emergencies in a foundation pit group, which significantly affects the deformation and safety of foundation pits. In this study, the deformation characteristics of a deep foundation pit group and the mutual interactions among the adjacent foundation pits were observed by a monitoring system during excavation. Field data of the foundation pit group, including the lateral deflections of the enclosure pile, the ground subsidence, as well as the vertical column movements, were analyzed and compared with individual excavations in Shanghai. The field data showed that the excavation of the adjacent foundation pit reduced the lateral deformation of the enclosure structure, caused by the reduction of active earth pressure acting on the retaining pile. Furthermore, the foundation pit excavated later caused upward movements of the soil between them. However, the foundation pit excavated earlier had a negligible influence on the vertical column movements of the foundation pit excavated later. Due to the optimized excavation sequence of the deep foundation pit group, the deformation of this special excavation was well controlled.