Abstract

The authors of presented research case focused on possibilities of sealing porous as well as non – porous materials and analysed the measured results. It is the second article of the above mentioned authors dealing with sealed joints, however, in this case study the focus was placed on a group of industrially manufactured modified silyl polymer and polyurethane sealants. The research is based on the modified test procedure for the determination of adhesion and cohesion properties during maintained extension at variable temperatures, i.e. a high temperature of (70 + 2) °C and a temperature simulating freezing, i.e. (-20 + 2) °C, according to the European standard EN ISO 9047. The degree of specimen extension was set to amplitude of 20.0 % and the aim of the research case was to discover any differences that might appear in the resistance. The measured results demonstrate that there are significant differences between individual sealants in the results they provide in combination with specific material, e.g. wood appears to be a problematic substrate as well as glass cement or aluminium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.