Abstract
This case history analyzes the bearing capacity failure of a 4-story reinforced concrete building in Benghazi, Libya, constructed in Fall 2000. The building has a plan area of 65 m² and is supported by an 80 cm thick raft foundation resting on collapsible sandy loess, which can lose shear strength when wet. Several months before the building's failure, nearby construction work caused a broken pipeline, leading to significant water leakage. This moisture infiltrated the soil under the foundation, reducing its bearing capacity, particularly on the northern side. In winter 2002, the building began to tilt northward due to this reduced capacity, although inspections revealed no structural cracks, attributed to the rigidity of the raft foundation and reinforced concrete shear walls. The paper discusses the geotechnical properties of the supporting soil and uses finite element analysis to show that the bearing pressures exceeded allowable limits under wet conditions, emphasizing the importance of moisture content in assessing soil stability. This case highlights the complexities of foundation design and the critical impact of environmental factors on soil behavior, advocating for thorough geotechnical assessments and ongoing monitoring of conditions around structural foundations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: World Journal of Advanced Engineering Technology and Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.