Abstract

This research aimed to develop a method to facilitate the implementation of prevention through design and apply it to a pump station case study in Manitoba, Canada. The method used, in part, failure mode and effects analysis and involved tasking experts with analyzing the project’s design documents to identify potential occupational health and safety failures that could occur throughout construction. It also entailed analyzing the project’s construction documents to determine actual, design-related, occupational health and safety failures observed throughout construction. The application of the method to that project identified 42 potential failure modes in the design, 38% of which were deemed high-risk. A total of 18 failures were detected throughout construction. Of these, 89% were predicted using failure mode and effects analysis and thus deemed preventable by design, indicating the potential effectiveness of the method. Future research should reapply it to other projects to validate these findings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.