Abstract

In this chapter, we illustrate the criticality of proper fitting of enzyme kinetic data. Simple techniques are provided to arrive at meaningful kinetic parameters, illustrated using an example, nonmonotonic dataset. In the initial analysis of this data set, derived Km and Vmax parametersincorporated into PBPK models resulted in outcomes that did not adequately describe clinical data. This prompted a re-review of the in vitro data set andcurve-fitting procedures. During this review, it was found that the 3-parameter model was fitted on data that was improperly unweighted. Reanalysis of the data using a weighted model returned a better fit and resulted in kinetic parameters better aligning with clinical data. Tools and techniques used to identify and compare kinetic models of this data set are provided, including various replots, visual inspection, examination of residuals, and the Akaike information criterion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.