Abstract

Introduction: The unicompartmental Oxford prosthesis has been used as a goodalternative for medial unicompartmental osteoarthritis because it is associated with earlyrehabilitation and a low rate of intraoperative complications. This case describes a rarecomplication during the procedure. Case Presentation: We present an intraoperative fracture of the medial condyle in a 70-year-old woman that was treated with 6.5 mm cannulated screws with a compressiontechnique. The patient remained in a non-weight bearing protocol for 6 weeks andreached a full range of mobility at 3 months. Complete radiological consolidation and agood functional outcome were observed. Conclusion: Intraoperative fractures benefit from a stable osteosynthesis that allows freerange of mobility and does not delay postoperative rehabilitation.

Full Text