Abstract
Introduction: The unicompartmental Oxford prosthesis has been used as a goodalternative for medial unicompartmental osteoarthritis because it is associated with earlyrehabilitation and a low rate of intraoperative complications. This case describes a rarecomplication during the procedure. Case Presentation: We present an intraoperative fracture of the medial condyle in a 70-year-old woman that was treated with 6.5 mm cannulated screws with a compressiontechnique. The patient remained in a non-weight bearing protocol for 6 weeks andreached a full range of mobility at 3 months. Complete radiological consolidation and agood functional outcome were observed. Conclusion: Intraoperative fractures benefit from a stable osteosynthesis that allows freerange of mobility and does not delay postoperative rehabilitation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.