Abstract

Summary: Extravasation of irrigation fluid during arthroscopy is a well-known complication. We report a case of accumulation of fluid into the calf during open wedge high tibial osteotomy combined with simultaneous arthroscopic anterior cruciate ligament (ACL) reconstruction. The main cause for fluid extravasation was the drilling of the tibial tunnel, which allowed the fluid to cross the osteotomy gap and invade the flexor compartments. Although an elevation of the intracompartmental pressure was measured, there was no clinical evidence of compartment syndrome. A subcutaneous release of the flexor compartment of the leg was performed. The patient suffered no further sequelae. High tibial osteotomy combined with simultaneous arthroscopic ACL reconstruction has to be performed carefully, and potential complications must be detected immediately to prevent compartment syndrome.Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 15, No 8 (November), 1999: pp 864–866

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.