Abstract

BackgroundIn the era of fluoroless catheter ablation (CA), achieving a successful transseptal puncture (TSP) presents a significant challenge. We introduce a novel technique for zero-fluoroscopy and cost-effective needle-free TSP.Case summaryWe describe two cases where a GMS-1 guidewire (0.025 inch, pigtail configuration; Toray Medical Co., Ltd., Japan) was utilized for TSP. This technique was performed using either fluoroscopy or intracardiac echocardiography (ICE). The procedure was completed successfully in both cases, with no complications reported.ConclusionThe use of a 0.025 inch GMS-1 guidewire with an electrocautery technique enables effective transseptal puncture without the need for a needle or fluoroscopy. This novel approach offers a safe, efficient, and zero-fluoroscopic alternative for TSP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.