AbstractA recent incident at the Eastman Chemical Company's Kingsport site involved a 20‐foot section of PTFE‐lined pipe that failed at a flange joint, resulting in a leak, but no injuries. Initial scene observations indicated that a section of the liner had disintegrated, leaving an open space where the liner forms the flange gasket. More detailed analysis showed that the entire liner was intact, but had retracted approximately 2.5 inches into the pipe.This paper will discuss the physical mechanisms (thermal cycling, viscoelastic properties of PTFE) that explain the liner retraction, as well as the installation factors (electrical tracing, liner length), which influenced the timing and nature of the failure mechanism.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.