Abstract

To compare clinical effects of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with profitated plate. From April 2015 to April 2019, 60 patients with complex calcaneal fractures were treated with open reduction and heteromorphic plate internal fixation, and were divided into experiment group and control group by implant bone substitutes, and 30 patients in each group. In experiment group, there were 21 males and 9 females aged from 18 to 71 years old with an average of (36.85±7.42) years old;19 patients were classified to type Ⅲ and 11 patients were type Ⅳ according to Sanders classification;implanted with artificial bone. While in control group, there were 23 males and 7 females aged from 20 to69 years old with an average of (37.26±7.38) years old;18 patients were classified to type Ⅲ and 12 patients were type Ⅳ according to Sanders classification; implanted with autogenous bone. Operation time, intraoperative blood loss, drying time of incision, fracture healing time and complications were compared between two groups, changes of preoperative and postoperative Böhler angle and Gissane angle were also compared, and Maryland scoring was applied to evaluate recovery of affected foot. Both of two groups were followed up from 3 to 15 months with an average of (10.15±2.67) months. Operation time and intraoperative blood loss in experiment group were (89.32±12.43) min, (101.64±5.13) ml, respectively;while in control group were (112.45±13.82) min, (119.01±5.26) ml, respectively;and there were statistical difference between two groups (P<0.05). There were no differences in drying time of incision, fracture healing time and complications between two groups(P>0.05). Preoperative and postoperative Böhler angle at 3 months in experiment group were (14.19± 2.47)°, (34.52±4.41)°;while in control group were (14.08±2.35)°, (33.67±4.36)°;preoperative and postoperative Gissane angel at 3 months in experiment group were (90.16±6.43)°, (131.45±9.83)°;while in control group were (90.11±6.37)°, (130.87±9.24)°;there were statistical significance in Böhler angle and Gissane angel compared with 3 months after operation and before operation between two groups (P<0.05);while no difference at 3 months after operation between two groups (P> 0.05). There were no statistical meaning in Maryland items, total score and good rate between two groups at the final following up (P>0.05). Artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with irregular plate have similar function in promoting fracture healing, drying time of incision, fracture healing time and complications, while artificial bone has better effects in reducing intraoperative blood loss, shorten operation time.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.