Abstract

For the conventional configuration of the single-phase electric springs, the electrolytic capacitor (E-cap) is required for buffering the double-line-frequency dc-link power. This demands large capacitance and constant average dc-link voltage for achieving sufficiently low-voltage ripples of the E-cap, which renders low efficiency and poor reliability of the ES. To address these issues, a cascaded voltage control scheme is proposed in this article. The proposed control scheme enables large fluctuations of the dc-link voltage so that the film capacitor (F-cap), which is of smaller capacitance and higher reliability, can be applied. In addition, the proposed control scheme can adaptively adjust the average dc-link voltage for achieving the minimum power loss of the ES. The quasi-steady-state and steady-state models of the electric-spring-based smart load are developed. The optimum average dc-link voltage for achieving the minimum power loss is analytically derived. The functionality and loss reduction capability of the proposed controller are verified through hardware experiments and simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call