Abstract
Multilevel converters have gained popularity in high-power applications due to their low switch voltage stress and modularity. Cascaded H-bridge converters are a promising breed of multilevel converters which generally require several independent dc sources. Recently, existence of a redundant switching state has been utilized to replace the independent voltage sources with capacitors except for the one with the highest voltage level. Redundancy in the charge and discharge modes of the capacitors is assumed to be adequate for their voltage regulation. However, output current of the inverter as well as the time duration of the redundant switching states have been neglected. In this paper, the impacts of connected load to the cascaded H-bridge converter as well as the switching angles on the voltage regulation of the capacitors are studied. This study proves that voltage regulation is only attainable in a much limited operating conditions that it was originally reported.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.