Abstract

We demonstrated an optical fiber sensor based on a cascaded fiber Fabry-Perot interferometer (FPI)-regenerated fiber Bragg grating (RFBG) for simultaneous measurement of temperature and strain under high temperature environments. The FPI is manufactured from a ∼74 µm long hollow core silica tube (HCST) sandwiched between two single mode fibers (SMFs). The RFBG is inscribed in one of the SMF arms which is embedded inside an alundum tube, making it insensitive to the applied strain on the entire fiber sensor, just in case the temperature and strain recovery process are described using the strain-free RFBG instead of a characteristic due-parameter matrix. This feature is intended for thermal compensation for the FPI structure that is sensitive to both temperature and strain. In the characterization tests, the proposed device has exhibited a temperature sensitivity ∼ 18.01 pm/°C in the range of 100 °C - 1000 °C and excellent linear response to strain in the range of 300 °C - 1000 °C. The measured strain sensitivity is as high as ∼ 2.17 pm/µɛ for a detection range from 0 µɛ to 450 µɛ at 800 °C, which is ∼ 1.5 times that of a FPI-RFBG without the alundum tube.