Abstract

The aim of this report is to obtain the two-dimensional performance of compressor cascade with high stagger. The results are as follows : 1) The test method to obtain two-dimensional performance of compressor cascades has been determined. 2) The tests were carried out successfully and the performances of compressor cascades were obtained for 31 combinations of the pitch chord ratio S/C=0.7, 1.0, 1.2, and the stagger angle ξ=45°, 50°, 60°, 65°to each of the camber Clo =0.0, 0.4, 0.8, 1.2. 3) The design points were selected and the design loading limits were derived from the cascade data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.