Abstract
The problem of controlling single-phase shunt active power filters is addressed in presence of nonlinear loads. The control objective is twofold: (i) compensation of harmonic and reactive currents absorbed by the nonlinear load, this objective is referred to as power factor correction (PFC); (ii) regulation of the inverter output capacitor voltage. A two-loop cascade control strategy is developed that includes an inner-loop designed, using the Lyapunov design approach, to cope with the compensation issue and an outer-loop designed to regulate the capacitor voltage. The controller performances are formally analysed using system averaging theory. The theoretical results are illustrated by simulation.