Abstract

Abstract This paper reports experimental results on the cascade control of a distributed collector solar field. The control problem consists of keeping constant the field outlet oil temperature by acting on the circulating oil flow used for heat transfer. In the inner loop an adaptive model based predictive controller exploiting the information conveyed by accessible disturbances (radiation changes and inlet oil temperature) is used, while in the outer loop a PID is employed. The need for adaptive control arises from the time varying behaviour of the plant. Due to the generality of the methods employed, the experience reported is relevant to a wide class of industrial processes.